summary




This device is applicable to MT386 "Test Methods and Judgment Rules for Flame retardancy of Flame Retardant Cables Used in Coal Mines" 0.5-300mm When flame retardant cables or flame retardant cable joints used in coal mines with one to three cores for power transmission need to undergo a load burning test on the sample. The MT386 standard also requires the tested sample to undergo flame retardant tests that meet the requirements of GBT18380. -2022 "Fire Test for Cables under Flame Conditions, Part 11: Vertical Combustion Method for Single Insulated Wire or Cable" and GB/T18380-2022 "Fire Test for Cables and Optical Cables under Flame Conditions, and Vertical Flame Spread Test for Vertically Installed Bundled Wires and Cables". Testers must thoroughly read MT386-2011 and its appendices, be familiar with and master the requirements of the standard for sample preparation, installation, and combustion device operating procedures, in order to successfully complete this test.


Technical parameter

2、 Basic parameters




Che Guo Dong Bao State Affairs State Center State




1. Main dimensions of equipment




Combustion rack and combustion chamber size: 1800 x500x1750mm




Electrical control box size: 700x650x1250mm




Combustion chamber size: 900 x 500x1100mm




2. Effective size of combustion chamber: 1100 x 500 x 900mm




3. Combustion burner: A burner that uses natural gas or methane as fuel and meets the GB/Z5169.15 standard with a power of 500W




4. Transformer output current range 1:0-100A




Range 2: 100-1000A




Range 3: 1000-3000A




Customizable range of 5000A




5. Transformer power: 50KVA




6. Sample temperature sensor: K-type, temperature measurement range: room temperature -300C